55 research outputs found

    Flow Dynamics in Human Aorta with Coexisting Models of Bicuspid Aortic Stenosis and Coarctation of the Aorta

    Get PDF
    Coarctation of the aorta (COA) is an obstruction of the aorta and is usually associated with bicuspid and tricuspid aortic valve stenosis (AS). The main objective of this work is to understand the hemodynamic of COA from different perspectives. This was performed using a global approach including: numerical simulations, mathematical lumped parameter modeling and experimental measurements. Numerous investigations pointed to a relationship between the genesis and the progression of cardiovascular disease and the locally irregular flow occurring at the diseased zone. Therefore, to examine the relationship between arterial disease and hemodynamics conditions, a joint experimental and numerical investigation was performed to understand physics of fluid flow of COA. When COA coexists with AS, the left ventricle faces a double hemodynamic load: a valvular load plus a vascular load. First, a formulation describing the instantaneous net pressure gradient through COA was introduced and the predictions compared to in vitro results. The model was then used to determine left ventricular work induced by coexisting aortic stenosis and coarctation with different severities. The suggested model can be used to guide the choice of optimal operative procedure (aortic valve replacement and/or coarctation repaired surgery) and to predict the potential outcome for such patients. Early detection and accurate estimation of COA severity is the most important predictor of successful long-term outcome. However, current clinical parameters used for the evaluation of the severity of COA have several limitations. In this study, first, we evaluated the limitations of current existing parameters (Catheter trans-COA pressure gradients and Doppler echocardiographic trans-COA pressure gradients) for the evaluation of the severity of COA. Then, we suggested a new approach based on COA Doppler velocity index and COA effective orifice area capable of predicting more accurately the severity of COA. An original in-vitro study was performed using a mock flow circulation model with different COA severities and various aortic valve conditions under different flow rates. In conclusion, this study investigated the flow dynamics of COA and development of a lumped parameter model, based on non-invasive measurements, capable of accurately investigating the impact of coexisting AS and COA on left ventricular workload. In addition, this study proposed two innovative approaches to evaluate the severity of COA correctly

    The role of aortic compliance in determination of coarctation severity: Lumped parameter modeling, in vitro study and clinical evaluation

    Get PDF
    Early detection and accurate estimation of the extent of coarctation of the aorta (COA) is critical to long-term outcome. Peak-to-peak trans-coarctation pressure gradient (PKdP) higher than 20 mmHg is an indication for interventional/surgical repair. Patients with COA have reduced proximal and distal aortic compliances. A comprehensive study investigating the effects of variations of proximal COA and systemic compliances on PKdP, and consequently on the COA severity evaluation has never been done. This study evaluates the effect of aortic compliance on diagnostic accuracy of PKdP. Lumped parameter modeling and in vitro experiments were performed for COA severities of 50%, 75% and 90% by area. Modeling and in vitro results were validated against retrospective clinical data of PKdP, measured in 54 patients with COA. Modeling and in vitro. PKdP increases with reduced proximal COA compliance (+36%, +38% and +53% for COA severities of 50%, 75% and 90%, respectively; p<0.05), but decreases with reduced systemic compliance (−62%, −41% and −36% for COA severities of 50%, 75% and 90%, respectively; p<0.01). Clinical study. PKdP has a modest correlation with COA severity (R=0.29). The main determinants of PKdP are COA severity, stroke volume index and systemic compliance. Systemic compliance was found to be as influential as COA severity in PKdP determination (R=0.30 vs. R =0.34). In conclusion, PKdP is highly influenced by both stroke volume index and arterial compliance. Low values of PKdP cannot be used to exclude the severe COA presence since COA severity may be masked by reduced systemic compliance and/or low flow conditions

    Hemodynamic Changes following Aortic Valve Bypass: A Mathematical Approach

    Get PDF
    Aortic valve bypass (AVB) has been shown to be a viable solution for patients with severe aortic stenosis (AS). Under this circumstance, the left ventricle (LV) has a double outlet. The objective was to develop a mathematical model capable of evaluating the hemodynamic performance following the AVB surgery. A mathematical model that captures the interaction between LV, AS, arterial system, and AVB was developed. This model uses a limited number of parameters that all can be non-invasively measured using patient data. The model was validated using in vivo data from the literature. The model was used to determine the effect of different AVB and AS configurations on flow proportion and pressure of the aortic valve and the AVB. Results showed that the AVB leads to a significant reduction in transvalvular pressure gradient. The percentage of flow through the AVB can range from 55.47% to 69.43% following AVB with a severe AS. LV stroke work was also significantly reduced following the AVB surgery and reached a value of around 1.2 J for several AS severities. Findings of this study suggest: 1) the AVB leads to a significant reduction in transvalvular pressure gradients; 2) flow distribution between the AS and the AVB is significantly affected by the conduit valve size; 3) the AVB leads to a significant reduction in LV stroke work; and 4) hemodynamic performance variations can be estimated using the model.Fonds quebecois de la recherche sur la nature et les technologies (176048

    Non-invasive determination of left ventricular workload in patients with aortic stenosis using magnetic resonance imaging and Doppler echocardiographye

    Get PDF
    Early detection and accurate estimation of aortic stenosis (AS) severity are the most important predictors of successful longterm outcomes in patients. Current clinical parameters used for evaluation of the AS severity have several limitations including flow dependency. Estimation of AS severity is specifically challenging in patients with low-flow and low transvalvular pressure gradient conditions. A proper diagnosis in these patients needs a comprehensive evaluation of the left ventricle (LV) hemodynamic loads. This study has two objectives: (1) developing a lumped-parameter model to describe the ventricular-valvular-arterial interaction and to estimate the LV stroke work (SW); (2) introducing and validating a new index, the normalized stroke work (N-SW), to assess the global hemodynamic load imposed on the LV. N-SW represents the global hemodynamic load that the LV faces for each unit volume of blood ejected. The model uses a limited number of parameters which all can be measured non-invasively using current clinical imaging modalities. The model was first validated by comparing its calculated flow waveforms with the ones measured using Cardiovascular Magnetic Resonance (CMR) in 49 patients and 8 controls. A very good correlation and concordance were found throughout the cycle (median root mean square: 12.21 mL/s) and between the peak values (r = 0.98; SEE = 0.001, p,0.001). The model was then used to determine SW using the parameters measured with transthoracic Doppler-echocardiography (TTE) and CMR. N-SW showed very good correlations with a previously-validated index of global hemodynamic load, the valvular arterial impedance (ZVA), using data from both imaging modalities (TTE: r = 0.82, SEE = 0.01, p,0.001; CMR: r = 0.74, SEE = 0.01, p,0.001). Furthermore, unlike , N-SW was almost independent from variations in the flow rate. This study suggests that considering N-SW may provide incremental diagnostic and prognostic information, beyond what standard indices of stenosis severity and provide, particularly in patients with low LV outflow

    Elimination of Transcoarctation Pressure Gradients Has No Impact on Left Ventricular Function or Aortic Shear Stress After Intervention in Patients With Mild Coarctation

    Get PDF
    Objectives: This study sought to investigate the impact of transcatheter intervention on left ventricular function and aortic hemodynamics in patients with mild coarctation of the aorta (COA). Background: The optimal method and timing of transcatheter intervention for COA remains unclear, especially when the severity of COA is mild (peak-to-peak transcoarctation pressure gradient  < 20 mm Hg). Debate rages regarding the risk/benefit ratio of intervention versus long-term effects of persistent minimal gradient in this heterogeneous population with differing blood pressures, ventricular function, and peripheral perfusion. Methods: We developed a unique computational fluid dynamics and lumped parameter modeling framework based on patient-specific hemodynamic input parameters and validated it against patient-specific clinical outcomes (before and after intervention). We used clinically measured hemodynamic metrics and imaging of the aorta and the left ventricle in 34 patients with mild COA to make these correlations. Results: Despite dramatic reduction in the transcoarctation pressure gradient (catheter and Doppler echocardiography pressure gradients reduced by 75% and 47.3%, respectively), there was only modest effect on aortic flow and no significant impact on aortic shear stress (the maximum time-averaged wall shear stress in descending aorta was reduced 5.1%). In no patient did transcatheter intervention improve left ventricular function (e.g., stroke work and normalized stroke work were reduced by only 4.48% and 3.9%, respectively). Conclusions: Transcatheter intervention that successfully relieves mild COA pressure gradients does not translate to decreased myocardial strain. The effects of the intervention were determined to the greatest degree by ventricular–vascular coupling hemodynamics and provide a novel valuable mechanism to evaluate patients with COA that may influence clinical practice. Key Words: aortic hemodynamics, left ventricle function, mild coarctation, peak-to-peak pressure gradient, transcatheter interventionNational Institute of Mental Health (U.S.) (R01 GM 49039)American Heart Association (Postdoctoral Fellowship 16POST26420039

    Mixed Valvular Disease Following Transcatheter Aortic Valve Replacement: Quantification and Systematic Differentiation Using Clinical Measurements and Image-Based Patient‐Specific In Silico Modeling

    Get PDF
    Background: Mixed valvular disease (MVD), mitral regurgitation (MR) from pre‐existing disease in conjunction with paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR), is one of the most important stimuli for left ventricle (LV) dysfunction, associated with cardiac mortality. Despite the prevalence of MVD, the quantitative understanding of the interplay between pre‐existing MVD, PVL, LV, and post‐TAVR recovery is meager. Methods and Results: We quantified the effects of MVD on valvular‐ventricular hemodynamics using an image‐based patient‐specific computational framework in 72 MVD patients. Doppler pressure was reduced by TAVR (mean, 77%; N=72; P<0.05), but it was not always accompanied by improvements in LV workload. TAVR had no effect on LV workload in 22 patients, and LV workload post‐TAVR significantly rose in 32 other patients. TAVR reduced LV workload in only 18 patients (25%). PVL significantly alters LV flow and increases shear stress on transcatheter aortic valve leaflets. It interacts with mitral inflow and elevates shear stresses on mitral valve and is one of the main contributors in worsening of MR post‐TAVR. MR worsened in 32 patients post‐TAVR and did not improve in 18 other patients. Conclusions: PVL limits the benefit of TAVR by increasing LV load and worsening of MR and heart failure. Post‐TAVR, most MVD patients (75% of N=72; P<0.05) showed no improvements or even worsening of LV workload, whereas the majority of patients with PVL, but without that pre‐existing MR condition (60% of N=48; P<0.05), showed improvements in LV workload. MR and its exacerbation by PVL may hinder the success of TAVR

    Mixed Valvular Disease Following Transcatheter Aortic Valve Replacement: Quantification and Systematic Differentiation Using Clinical Measurements and Image-Based Patient‐Specific In Silico Modeling

    Get PDF
    Background: Mixed valvular disease (MVD), mitral regurgitation (MR) from pre‐existing disease in conjunction with paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR), is one of the most important stimuli for left ventricle (LV) dysfunction, associated with cardiac mortality. Despite the prevalence of MVD, the quantitative understanding of the interplay between pre‐existing MVD, PVL, LV, and post‐TAVR recovery is meager. Methods and Results: We quantified the effects of MVD on valvular‐ventricular hemodynamics using an image‐based patient‐specific computational framework in 72 MVD patients. Doppler pressure was reduced by TAVR (mean, 77%; N=72; P<0.05), but it was not always accompanied by improvements in LV workload. TAVR had no effect on LV workload in 22 patients, and LV workload post‐TAVR significantly rose in 32 other patients. TAVR reduced LV workload in only 18 patients (25%). PVL significantly alters LV flow and increases shear stress on transcatheter aortic valve leaflets. It interacts with mitral inflow and elevates shear stresses on mitral valve and is one of the main contributors in worsening of MR post‐TAVR. MR worsened in 32 patients post‐TAVR and did not improve in 18 other patients. Conclusions: PVL limits the benefit of TAVR by increasing LV load and worsening of MR and heart failure. Post‐TAVR, most MVD patients (75% of N=72; P<0.05) showed no improvements or even worsening of LV workload, whereas the majority of patients with PVL, but without that pre‐existing MR condition (60% of N=48; P<0.05), showed improvements in LV workload. MR and its exacerbation by PVL may hinder the success of TAVR

    Impact of TAVR on coronary artery hemodynamics using clinical measurements and image‐based patient‐specific in silico modeling

    No full text
    Abstract In recent years, transcatheter aortic valve replacement (TAVR) has become the leading method for treating aortic stenosis. While the procedure has improved dramatically in the past decade, there are still uncertainties about the impact of TAVR on coronary blood flow. Recent research has indicated that negative coronary events after TAVR may be partially driven by impaired coronary blood flow dynamics. Furthermore, the current technologies to rapidly obtain non-invasive coronary blood flow data are relatively limited. Herein, we present a lumped parameter computational model to simulate coronary blood flow in the main arteries as well as a series of cardiovascular hemodynamic metrics. The model was designed to only use a few inputs parameters from echocardiography, computed tomography and a sphygmomanometer. The novel computational model was then validated and applied to 19 patients undergoing TAVR to examine the impact of the procedure on coronary blood flow in the left anterior descending (LAD) artery, left circumflex (LCX) artery and right coronary artery (RCA) and various global hemodynamics metrics. Based on our findings, the changes in coronary blood flow after TAVR varied and were subject specific (37% had increased flow in all three coronary arteries, 32% had decreased flow in all coronary arteries, and 31% had both increased and decreased flow in different coronary arteries). Additionally, valvular pressure gradient, left ventricle (LV) workload and maximum LV pressure decreased by 61.5%, 4.5% and 13.0% respectively, while mean arterial pressure and cardiac output increased by 6.9% and 9.9% after TAVR. By applying this proof-of-concept computational model, a series of hemodynamic metrics were generated non-invasively which can help to better understand the individual relationships between TAVR and mean and peak coronary flow rates. In the future, tools such as these may play a vital role by providing clinicians with rapid insight into various cardiac and coronary metrics, rendering the planning for TAVR and other cardiovascular procedures more personalized

    Instantaneous streamlines at peak of the systole.

    No full text
    <p>In the case of a normal aorta, the flow is laminar and fully attached to the wall. The presence of a COA significantly alters the flow dynamics in the aorta. The flow detaches from the aortic wall and develops into a high-speed eccentric jet downstream of the COA and the BAV.</p
    corecore